General IconGeneral
Operating Voltage24 V DC
Safety outputs2
Response time≤ 20 ms
Protection classIP20
Housing materialPlastic
Safety Integrity LevelSIL 3
Performance LevelPL e
Number of Outputs2
MountingDIN rail
Supply voltage24 V DC
Current consumption≤ 100 mA
Output typeSemiconductor
Switching current≤ 0.5 A
ConnectionScrew terminals

Summary

On safety

Qualified safety personnel

Defines the requirements for personnel qualified to mount, commission, and service the safety controller.

Applications of the device

Describes the Flexi Classic's capabilities as a configurable control system for safety applications.

Correct use

Specifies the intended use of the Flexi Classic safety controller and potential warranty voidance.

General safety notes and protective measures

Provides essential safety guidelines, standards, and directives for installation and use.

Product description

UE410-MU main module

Details the UE410-MU as the primary module for system configuration, inputs, and outputs.

UE410-GU main module

Details the UE410-GU as an alternative main module, including global emergency stop capabilities.

UE410-XU module

Describes the UE410-XU as an input/output extension module with identical functionality to UE410-MU.

Special applications and functions

Muting function

Explains how muting temporarily overrides safety devices for material transport.

Mountingdismantling

Steps for mounting the modules

Provides instructions for correctly mounting the Flexi Classic modules onto a DIN mounting rail.

Electrical installation

Electrical installation

Covers general electrical installation requirements, EMC compliance, and wiring guidelines.

Application examples and connection diagrams

Global emergency stop with two UE410-GU

Shows a connection example for a global emergency stop system using two UE410-GU modules.

Commissioning

Validation of the application

Outlines the essential test points for validating the safety application before commissioning.

Test notes

Provides guidelines for initial tests, regular testing, and inspections by qualified personnel.

Configuration

Accepting the system configuration

Explains the procedure for accepting and saving the system configuration using the ENTER button.

Diagnostics

In the event of faults or errors

Guides on how to cease operation, identify faults, and perform functional tests.

Error indications of the ERR error LED

Explains the meaning of ERR LED indications and their corresponding rectification steps.

Technical specifications

UE410-8 DI input extension module

Lists the technical specifications for the UE410-8DI input extension module.