Chapter 2 Operating instructions
Flexi Classic
14 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8011509/YPP0/2015-10-26
Subject to change without notice
On safety
2.5 Environmental protection
The Flexi Classic modular safety controller has been designed to minimise environmental
impact. It uses only a minimum of power and natural resources.
= At work, always act in an environmentally responsible manner.
2.5.1 Disposal
Disposal of unusable or irreparable devices should always occur in accordance with the
applicable country-specific waste-disposal regulations (e.g. European Waste Code
16 02 14).
We would be pleased to be of assistance to you on the disposal of these devices.
Contact us.
2.5.2 Separation of materials
Material separation may only be performed by qualified safety personnel!
Caution is required when dismantling devices. There is a risk of injuries.
Before you send the devices for appropriate recycling, it is necessary to separate the
different materials in the Flexi Classic.
= Separate the housing from the rest of the parts (in particular the circuit board).
= Send the separated components for recycling as appropriate (see Tab. 5).
Components Disposal
Product
Housing, circuit boards, cables,
connectors and electrical connecting
pieces
Electronic recycling
Packaging
Cardboard, paper
Paper/cardboard recycling
Note
WARNING
Tab.
5
:
Overview on
by components

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK UE410-MU and is the answer not in the manual?

SICK UE410-MU Specifications

General IconGeneral
Operating Voltage24 V DC
Safety outputs2
Response time≤ 20 ms
Protection classIP20
Housing materialPlastic
Safety Integrity LevelSIL 3
Performance LevelPL e
Number of Outputs2
MountingDIN rail
Supply voltage24 V DC
Current consumption≤ 100 mA
Output typeSemiconductor
Switching current≤ 0.5 A
ConnectionScrew terminals