Operating instructions Chapter 4
Flexi Classic
8011509/YPP0/2015-10-26 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 73
Subject to change without notice
Special applications and
functions
4.8 SICK muting sensors
Sensor Type Switching output Q type
WT24-2
WT27-3
Photoelectric proximity
switch
WT260
Light switching
WL23-2
WL27-3
WL260
WL12-3
WL14-2
Photoelectric reflex switch
WL18-3
Dark switching
WS/WE24-2
WS/WE27-3
Through-beam photoelectric
switch
WS260/WE260
Dark switching
For the selection and settings for the SICK optical muting sensors in muting applications,
the following applies:
The outputs must be PNP switching.
Other type series are possible.
Tab.
32
:
Selection of the
optical SICK muting sensors
Notes

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK UE410-MU and is the answer not in the manual?

SICK UE410-MU Specifications

General IconGeneral
Operating Voltage24 V DC
Safety outputs2
Response time≤ 20 ms
Protection classIP20
Housing materialPlastic
Safety Integrity LevelSIL 3
Performance LevelPL e
Number of Outputs2
MountingDIN rail
Supply voltage24 V DC
Current consumption≤ 100 mA
Output typeSemiconductor
Switching current≤ 0.5 A