92
6 WIRING
6.2 Terminal Arrangement
6.2 Terminal Arrangement
This section explains the terminal arrangement of a safety extension module.
FX5-SF-MU4T5
The terminal arrangement of an FX5-SF-MU4T5 is as follows.
The following combinations of input terminals should be considered when wiring input terminals redundantly.
I0 terminal and I1 terminal
I2 terminal and I3 terminal
The following combinations of output terminals should be considered when wiring output terminals
redundantly.
Q0 terminal and Q1 terminal
Q2 terminal and Q3 terminal
Left side of terminal arrangement Right side of terminal arrangement
Name Description Name Description
I0 Safety input 0 Q0 Safety output 0
I1 Safety input 1 Q1 Safety output 1
I2 Safety input 2 Q2 Safety output 2
I3 Safety input 3 Q3 Safety output 3
X0 General input 0 T0 Test output 0
X1 General input 1 T1 Test output 1
X2 General input 2 XS0 ENABLE input
+ External 24 V
+24 V terminal
- External 24 V
Ground terminal
FG Frame ground FG Frame ground