EasyManua.ls Logo

SICK MITSUBISHI ELECTRIC MELSEC iQ-F Series - Performance Specifications

SICK MITSUBISHI ELECTRIC MELSEC iQ-F Series
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
2 SPECIFICATIONS
2.4 Performance Specifications
2.4 Performance Specifications
The following shows the performance specifications.
Safety inputs of an FX5-SF-MU4T5
*1 The minimum switch-off time is the minimum time takes until a switch-off condition is detected after a module is switched off.
*2 A response time without any sensors. When sensors are connected, the data of the connected sensors is applied and the minimum
switch-off time is extended.
*3 The time from when a muting condition is enabled (I2/I3 are turned ON) until a muting function is activated.
*4 Indicates the maximum switch-off time when a muting error occurs.
*5 A muting input (I2 or I3) keeps OFF for the specified period of time.
*6 A time from when an ERROR LED starts flashing.
General inputs of an FX5-SF-MU4T5
Item Specification
Number of inputs 4 points
Input voltage (ON) 13 VDC to 30 VDC
Input voltage (OFF) -5 VDC to 5 VDC
Input current (ON) 3 mA (2.4 mA to 3.8 mA)
Input current (OFF) -2.5 mA to 2.1 mA
Input response time (filter delay) 2 ms
Indication of input operation LED lights when an input is ON.
Minimum switch-off time
*1,*2
(I0/I1) Program 1, 2, 4, 5, 6, and 9 24 ms
Program 3.1, 7, and 8 4 ms
Program 3.2 76 ms/24 ms
Minimum switch-off time
*1,*2
(I2/I3) Program 4, 5, and 6 24 ms
Program 1, 2, 3, 7, 8, and 9 4 ms
Power-up time 70 ms
Synchronous time monitoring Program 1 and 2 1500 ms
Program 4 and 5 500 ms
Muting ON
*3
Program 3 61 ms
Muting OFF Program 3 61 ms (165 ms
*4
)
Muting gap suppression
*5
Program 3 94 ms to 100 ms
Reset time 106 ms
Maximum teach-in time of the ENTER button
*6
3 s
Duration of actuation of a reset button (X0 and X1) 50 ms to 5 s
Item Specification
Number of inputs 4 points (3 general inputs/1 ENABLE input)
Input voltage (ON) 13.0 VDC to 30.0 VDC
Input voltage (OFF) -5.0 VDC to 5.0 VDC
Input current (ON) 3 mA (2.4 mA to 3.8 mA)
Input current (OFF) -2.5 mA to 2.1 mA
Indication of input operation LED lights when an input is ON.
Minimum switch-off time (XS0) 4 ms