44
4 FUNCTIONS
4.2 Built-In Program Selection Function
8 Bypass Connect two safety inputs (I0/I1 or
I4/I5) of either INPUT A or INPUT B
in dual-channel, and link them to
logic path A or B of an FX5-SF-
MU4T5 as the trigger of a bypass
function.
For details, refer to the following:
Page 76 Bypass
N/C + N/C N/C + N/C 
(1) Connect logic path A
with bypass
(2) Connect logic path B
with bypass
9 All paths batch
connection
Centralize all safety inputs of
INPUT A and INPUT B into one
AND logic, OR logic, or bypass, and
connect it to either logic path A or B
of an FX5-SF-MU4T5.
 A program overview differs
depending on the
combination of INPUT A
and INPUT B rotary switch
settings.
For details, refer to the
following:
Page 45 Details of
FX5-SF-8DI4 program 9
Prog
ram
Overview Description Logic path A
connection (l0/l1, l2/l3)
Logic path B
connection (l4/l5, l6/l7)
Program overview
Input
device
(1) (2) Input
device
(1) (2)
I0 I1 I2 I3
I4
I5 I6 I7
(1)
(2)