4 FUNCTIONS
4.3 Off Delay Delay Setting Function
69
4
Precautions
Applying a setting
The program does not run only by selecting a built-in program using the rotary switch(es).
To run the selected built-in program, settings must be applied.
For the procedure for applying the settings, refer to the following:
Page 112 Applying a setting
Rearranging the wiring of X0, X1, and X2 after the settings have been applied will cause an error.
Setting a control function
Depending on the wiring status of X0, X1, and X2, set an appropriate control function (restart interlock, external device
monitoring (EDM), or retriggering of the delayed OSSDs).
Inspection of the connected device
Before changing the program, check if the connected devices operate properly.
For the inspection, refer to the following:
Page 114 COMMISSIONING