12 Technical data
Table 13: Technical data
Cylinder type C-slot
Detection zone 0 ... 50mm
1)
Supply voltage U
B
10 ... 30V DC
Power consumption ≤550mW
Required magnetic field strength, typ. ≥ 2mT
overrun distance can be configured
Hysteresis can be configured
Time delay before availability 0.15s
Resolution typ. 0.01mm
Linearity typ. 0.3mm
2)
Repeatability (response time) typ. 0.05mm
3)
Sampling rate min. 2kHz
IO-Link 1.1
Enclosure rating IP67
Protection class III
Circuit protection A, B, D
4)
Ambient temperature, operation –20°C ... +70°C
1)
Deviations are possible depending on the drive.
2)
At 25°C, the linearity error (maximum deviation) depends on response curve and minimum deviation
function.
3)
At 25°C, repeatability with magnet movement from one direction.
4)
A = UB connections reverse polarity protected
B = Inputs and outputs reverse polarity protected
C = Interference suppression
D = Outputs overcurrent and short-circuit protected
TECHNICAL DATA 12
8028195/2022-11-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-G with 2/3 switching points and IO-Link (up to 8 switching points)
51