Technical specifications
64 © SICK AG · Germany · All rights reserved · Subject to change without notice
8013889/ZML0/2017-06-09
Operating Instructions
NAV350 Laser positioning sensor
Chapter 9
Beam divergence 5.0 mrad
Laser diode (wavelength) Infrared light (λ = 905 nm)
Pulse frequency 11.5 kHz
Laser class of the device
Class 1 as per IEC 60825-1:2014, eye safe, complies
with
21CFR 1040.10 and 1040.11 expect for deviations pursuant
to Laser Notice No. 50, dated June 24, 2007.
RS-232 data interface 19.200; 38.400; 57.600; default: 115.200 Bd
Data format Variable; default: 8 data bits, 1 stop bit, even parity
Output signal switching device 100 MBit/s, TCP/IP
Operating voltage Semiconductor output, active high,
maximum output current 0.5 A at DC 24 V
Power consumption for elec-
tronics
DC 24 V ±15%/IEC 60364-4-41 (VDE 0100 part 410)
EMC test Switching on: max. 36 W (1.5 A) at DC 24 V, on power up briefly
2.1 A
Housing According to EN 61000-6-2 (2005-08)/EN 61000-6-4 (2007-01)
Housing Aluminium die-cast
Enclosure rating III according to EN 61140 (2002-03)
Enclosure rating IP 65 according to EN 60529 (1991-10); A1 (2002-02)
Vibration test According to IEC 60068-2-6, table 2c (frequency range
10 150 Hz, amplitude 0,35 mm or 5 g)
Weight Approx. 2.4 kg
Ambient operating tempera-
ture/storage temperature
0 … +50 °C/–20 … +80 °C
Max. relative air humidity 5 … 85 %, non-condensing
1) The technical data are typical values at 25 °C for operation in industrial environments for standing AGV and
when using cylindrical reflectors with a diameter of 80 mm (3.15 in) from reflective tape 983-10 (article No.
5320565). Further conditions are: At least six reflectors must be seen per measurement, there must be an
equal number of reflectors on each side of the route, the angle between two reflectors must not be more than
120°.
2) Condition: laser spot completely on the target, warm-up time min. 30 min.
3) Valid for position queries using the telegram
MNPOSGETPOSE.
4) The technical data are typical values for operation in an industrial environment at 25 °C with the AGV station-
ary and on the usage of cylindrical reflectors with a diameter of 80 mm (3.15 in).
5) The data are typical values, condition: laser spot completely on the target, warm-up time min. 30 min.
6) Condition: laser spot completely on the target, warm-up time min. 30 min.
Feature NAV350
Tab. 17: Data sheet NAV350