EasyManua.ls Logo

SICK RFU62 Series - Page 116

SICK RFU62 Series
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
Trigger sensor, e.g. for read cycle generation
2
External supply voltage V
S ext
3
Input voltage V
in
4
PNP sensor
5
Supply voltage V
S
Table 54: Assignment of placeholders to the external digital switching inputs
CDB650-204 Device
Terminal A Signal B External input C
16 EXT. IN 1 1
17 EXT. IN 2 2
Function of switch S3
Table 55: Switch S3: SGND - GND
Switch setting Function
ON GND of the trigger sensor connected with GND of CDB650-204 and
CMC600.
OFF Trigger sensor connected potential-free at CDB650-204 and CMC600.
Common, isolated reference potential of all digital switching inputs is
SGND.
Functional principle of the external switching inputs
As a software-controlled operation, the CMC600 automatically transmits the output
states of its physical digital switching inputs “EXT. IN 1” and “EXT. IN 2” in the connec‐
tion module via the connecting cable to the serial Aux interface of the device. The
device internally implements the states for its logical inputs “External input 1” and
“External input 2”.
NOTE
The external digital switching inputs are software-defined. This results in a delay of max‐
imum 15 ms when transmitting the signal input at the CMC600 to the device.
Characteristic data of digital switching inputs
Table 56: Characteristic data of the digital switching inputs “External input 1” and “External
input 2”
Switching behavior Power to the input starts the assigned function, e.g. start read cycle.
Default setting in the device: logic not inverted (active high), debounce
time 10 ms
Properties
Opto-decoupled, reverse polarity protected
Can be wired with PNP output of a trigger sensor
Electrical values Low: V
in
≤ 2 V; I
in
≤ 0.3 mA
High: 6 V ≤ V
in
≤ 30 V; 0.7 mA ≤ I
in
≤ 5 mA
NOTE
Assign the functions for the external digital switching inputs in the device with a config‐
uration tool, e.g. the configuration software SOPAS ET.
14.6.9 Wiring the “Result 1” and “Result 2” digital switching outputs of the device in the CDB650-204
Device = RFU62x-101xx (Ethernet variant)
14 ANNEX
116
O P E R A T I N G I N S T R U C T I O N S | RFU62x 8015930/ZTM0/2018-11-06 | SICK
Subject to change without notice