RES/OUT C
8 7
2
5
Figure 65: Wiring digital switching outputs “Result 1” and “Result 2” of the device in the connection module CDB650-204
1
Device
2
Supply voltage V
S
3
Connection cable 1:1 (female connector, M12, 17-pin, A-coded / male connector, M12, 17-pin, A-coded)
4
Load (e.g. PLC)
5
Output voltage V
out
6
With inductive load: see note
7
Connection module: female connector, M12, 17-pin, A-coded
8
Device: male connector, M12, 17-pin, A-coded
Inductive load
NOTE
Provide an arc-suppression circuit at the digital switching output if an inductive load is
present.
b
Attach a freewheeling diode directly to the load for this purpose.
Table 57: Assignment of placeholders to digital switching outputs
Device CDB650-204
Output A Pin B Signal C Terminal D
Result 1 13 RES/OUT 1 20
Result 2 14 RES/OUT 2 21
Characteristic data of digital switching outputs
Table 58: Characteristic data of the digital switching outputs “Result 1” and “Result 2”
Switching behavior PNP switching to supply voltage U
V
Default settings in the device: no function, logic: not inverted (active
high)
Properties
•
Short-circuit protected + temperature protected
•
Not electrically isolated from V
S
ANNEX 14
8015930/ZTM0/2018-11-06 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU62x
117