Device 1 CDM420-0001 Host
5
.
.
.
TD+
TD‒
RD+
RD‒
RD+
RD‒
TD+
TD‒
GND
GND
GND
11
12
1
5 8
9
6
7
6
24
T+
34
T‒/TxD
25
R+
35
R‒/RxD
36
GND
6
Shield
RS-422 RS-422
ON
OFF
S2 : RS 485
ON
OFF
S3: Term 422
S2
OFF
S3
OFF
120 Ω
2
3
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
110
15
6
11
5
5 4
Figure 70: Wiring data interface RS-422 of the device in the connection module CDM420-0001
1
Device
2
RFU62x-104xx (serial variant): connecting cable permanently connected with the device (male connector, D-Sub-HD,
15-pin)
3
RFU62x-101xx (Ethernet variant): adapter cable (male connector, D-Sub-HD, 15-pin / female connector, M12, 17-pin, A-
coded)
4
Connection module: female connector, D-Sub-HD, 15-pin
5
RFU62x-101xx (Ethernet variant): male connector, M12, 17-pin, A-coded
Function of switch S3
Table 62: Switch S3: Term 422
Switch setting Function
ON Terminates the RS-422 receiver in the device to improve the noise ratio
on the line.
OFF No termination
NOTE
User of the RS-422 data interface:
•
The relevant interface drivers for the device comply with the standard in accor‐
dance with RS-422 and RS-485.
•
The connection shown above is configured for operation of the host with perma‐
nently activated drivers (often described as “RS-422 operation”), i.e. not RS-485
operation.
•
Activate the RS-422 data interface (“Point-to-Point” option) in the device with a
configuration tool, e.g. the configuration software SOPAS ET.
14.7.5 Wiring serial host interface RS-485 of the device in CDM420-0001
Device = RFU62x-104xx (serial variant), RFU62x-101xx (Ethernet variant)
ANNEX 14
8015930/ZTM0/2018-11-06 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU62x
123