EasyManua.ls Logo

SICK RFU62 Series - Page 122

SICK RFU62 Series
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Device 1 CDM420-0001 Host
5
.
.
.
TxD
RxD
RxD
TxD
GND
GND
GND
12
1
9
7
6
34
T/TxD
35
R/RxD
36
GND
6
Shield
RS-232 RS-232
ON
OFF
S2 : RS 485
ON
OFF
S3: Term 422
S2
OFFON
2
3
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
110
15
6
11
5
5 4
Figure 69: Wiring data interface RS-232 of the device in the connection module CDM420-0001
1
Device
2
RFU62x-104xx (serial variant): connecting cable permanently connected with the device (male connector, D-Sub-HD,
15-pin)
3
RFU62x-101xx (Ethernet variant): adapter cable (male connector, D-Sub-HD, 15-pin / female connector, M12, 17-pin, A-
coded)
4
Connection module: female connector, D-Sub-HD, 15-pin
5
RFU62x-101xx (Ethernet variant): male connector, M12, 17-pin, A-coded
NOTE
Activate the RS-232 data interface in the device with a configuration tool, e.g. the con‐
figuration software SOPAS ET.
14.7.4 Wiring serial host interface RS-422 of the device in CDM420-0001
Device = RFU62x-104xx (serial variant), RFU62x-101xx (Ethernet variant)
14 ANNEX
122
O P E R A T I N G I N S T R U C T I O N S | RFU62x 8015930/ZTM0/2018-11-06 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK RFU62 Series

Related product manuals