Figure 90: Wiring external digital switching outputs “Aux Out 1” and “Aux Out 2” of the device in the connection module
CDM420-0006
1
Device
2
Logical “External output” in the device
3
The optional parameter cloning module CMC600 is required in the connection module in order to be able to use the
additional external digital switching inputs and outputs of the device
4
Load (e.g. PLC)
5
Output voltage V
out
6
With inductive load: see note
Inductive load
NOTE
Provide an arc-suppression circuit at the digital switching output if an inductive load is
present.
b
Attach a freewheeling diode directly to the load for this purpose.
Table 85: Assignment of placeholders to digital switching outputs
Device CDM420-0006
External output A Signal B Terminal C
1 Aux Out 1 40
2 Aux Out 2 30
Functional principle of the external switching outputs
The device outputs the output states of its logical outputs “External output 1” and
“External output 2” via its serial Aux interface. By means of a software-controlled opera‐
tion, the CMC600 automatically adopts the states via the connecting cable and sets
them on its physical digital switching outputs “Aux Out 1” and “Aux Out 2” in the con‐
nection module.