Table 5: Overview of product features and functions of the device
Product feature/func‐
tion
Characteristic
Security and ease of
use
Rugged, compact metal housing, CE marking (Europe)
Automatic self-test at system start
Diagnostic tools for device setup and (remote) device monitoring
Configurable output of the read results including read diagnostics
data in two output formats
Operating data polling and, in the event of an error, output of codi‐
fied error messages on request
Activatable test string function (heartbeat) to signal that the device
is ready for operation
Future-proof due to firmware update via data interface
Future-proof SOPAS ET configuration software with password-pro‐
tected configuration mode
SICK AppSpace ready: The device already includes sensor apps for
integrating it into existing communication networks
Low power consumption
Wide supply voltage range
Large ambient temperature range. For details, see "Technical data",
page 82
Parameter cloning (to back up the configuration data in the internal
device memory):
°
Externally by inserting a microSD memory card
1)
into the device
°
Externally via the CMC600 parameter cloning module
1)
in the
CDB
1)
or CDM
1)
connection module (function not supported for
RFU62x-105x)
Convenient operation/
configuration
Configuration (online/offline) using the SOPAS ET configuration soft‐
ware
Single Tag ID Wizard (assistant) to help with initial configuration
Configuration and starting of device functions via a web server or
command strings
Optional function blocks for easier integration into PLC programs
PROFINET single port (RFU62x-101xx, RFU62x-105xx): Configura‐
tion via GSD parameterization
Application-specific programming using the SICK AppStudio devel‐
opment environment.
Further information on this is available online at: www.sick.com/
SICK_AppStudio
Status and process feedback indicators via LEDs
Reading Operation
Mode
Start/stop operation: For reading one or more transponders during
a read cycle.
Read cycle
Read cycle start condition is configurable in the object trigger con‐
trol settings: switching inputs etc.
Read cycle stop condition is configurable in the object trigger con‐
trol settings: switching inputs etc.
Radio interface(s)
Internal antenna
Transponder Process‐
ing
Base model RFU620 supports all standard passive transponders
that are compatible with EPCglobal UHF Class 1 Generation 2 or
ISO/IEC-18000-6C
Reading, writing, and multiple overwriting of the data on the
transponders, depending on the application
The data-supplying device is a component of a system for complete
visualization of the data within the process chain
Transponder Manage‐
ment
Decoding of the UII in HEX, BIN and ASCII. Supports GS1 TDS and
other industry-specific standards such as VDA55xx.
PRODUCT DESCRIPTION 3
8015930/ZTM0/2018-11-06 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU62x
21
Subject to change without notice

Table of Contents

Other manuals for SICK RFU62 Series

Related product manuals