This function is initiated by using the “permanent” option to save the internal
parameter set, e.g. via the SOPAS ET configuration software.
°
The function is used, among other things, to conveniently transfer the para‐
meter set to an replacement device of the same type in the event of an fault.
°
Optional external media include a microSD memory card that can be inserted
into the device, or the CMC600 parameter storage module in the CDB or
CDM connection module. Only the microSD memory card option is available
for the RFU62x-105xx.
•
Recording of diagnostic read data
Continuous recording of diagnostic read data after the first manual start, e.g., via
SOPAS ET. Recording is resumed after a device restart if the function has been
permanently set.
•
Other functions on request.
We recommend using an empty memory card when storing a parameter set for the first
time (if necessary, use a PC and card reader to check and delete the contents of the
card).
NOTE
Only use types approved by SICK to ensure reliable function of the memory card. You
can find these as accessories online at:
•
www.sick.com/RFU62x
The memory cards have no write protection that can be activated.
Indication of operational readiness
The “microSD” optical indicator shows the status of the memory card after installation
in the device. It lights up in different colors according to the status, see "Optical status
indicators on the display panel", page 71.
NOTICE
Possible data loss!
When the indicator is green (operational), this does not mean that the device is actually
accessing the memory card for reading or writing.
b
Do not remove the memory card or switch off the supply voltage while the device is
performing the following actions via the SOPAS ET configuration software:
■
Changing the parameter values by saving using the “permanent” option.
■
Starting functions that access the memory card (e.g. concurrent logging of
data)
Inserting the memory card in the device:
NOTICE
Risk of damage to the memory card!
b
To safely install the memory card, make sure there is no power to the device
before you insert it.
Ensure the IP67 or IP65 enclosure rating of the device is maintained, see "Conditions
for specified enclosure rating", page 11.
The card slot on the device is located under the cover foil on the side opposite the con‐
nections.
PRODUCT DESCRIPTION 3
8015930/ZTM0/2018-11-06 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU62x
23