12.1.2 Interfaces
Table 24: Technical data for RFU63x-131xx: Interfaces
RFU63x-131xx
Ethernet Host for data output (read result)
Aux for service
1)
Protocol: TCP/IP
Data transmission rate 10/100 Mbit/s
Supported services and protocols (e.g. DHCP, HTTP/HTTPS ...), see
type-specific online data sheet at: www.sick.com/RFU63x
PROFINET
2)
PROFINET single port
PROFINET dual port: Via external fieldbus module CDF600-22xx
4)
to PROFINET (2-port Ethernet) for data output (read result).
Data transmission rate 10/100 Mbit/s
EtherNet/IP Data transmission rate 10/100 Mbit/s
EtherCAT®
2)
Via external fieldbus module CDF600-0300
4)
(gateway mode) to
EtherCAT® (Ethernet) for data output (read result)
Serial RS-232, RS-422/485
Host for data output (read result)
Aux (only RS-232) for service
1)
Data transmission rate: 0.3 kBd ... 115.2 kBd, Aux: 57.6 kBd
CAN Host, data transmission rate: 20 kBit/s ... 1 MBit/s.
Bus length depends on data transmission rate and length of
cable. Typical: 250 m at 250 kBit/s and wire cross-section
0.34 mm
2
Protocols:
CSN (SICK CAN sensor network)
CANopen®
PROFIBUS
2)
Via external fieldbus module CDF600-21xx
4)
to PROFIBUS
(RS-485) for data output (read result)
USB
3)
Aux (USB 2.0) for service
1)
Digital switching inputs 2 x physical. Optional 2 x additional external logical inputs (soft‐
ware-controlled) via module CMC600
4)
in the CDB
4)
or CDM con‐
nection module
4)
V
in
= max. 30 V, I
in
= max. 5 mA
Opto-decoupled, reverse polarity protected, adjustable debounce
time
Digital switching outputs 2 x physical. Optional 2 x additional external logical outputs (soft‐
ware-controlled) via module CMC600
4)
in the CDB
4)
or CDM con‐
nection module
4)
V
out
= V
S
– 1.5 V, I
out
≤ 100 mA (typical)
Short-circuit protected, temperature protected, not electrically iso‐
lated from the supply voltage
Antenna Sending and receiving
1 x internal, 3 x external
Optical indicators 7 x RGB LEDs (status indicators) on front top
1 x RGB LED (process feedback) in front center Display function
can be set with pre-defined color assignment
5)
.
Acoustic indicator Beeper (buzzer), can be deactivated.
Function for event signaling and volume adjustable
5)
Operating elements 2 x pushbuttons (select and start/stop functions)
Configuration SOPAS ET configuration software, CoLa commands (telegrams),
web server, fieldbus controller (PLC) with additional support by
SICK function blocks
TECHNICAL DATA 12