EasyManua.ls Logo

SICK RFU62 Series - Page 247

SICK RFU62 Series
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
...
ð
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
1 2
Figure 40: Adapter cable, e.g. part no. 2070425 (3 m)
1
Female connector, M12, 17-pin, A-coded (view from front)
2
Illustration may differ
Table 34: Signal assignment of adapter cable with open end
Pin Signal Function Wire color
1 GND Ground Blue
2 V
S
Supply voltage Brown
3 CAN L CAN bus (IN/OUT) Green
4 CAN H CAN bus (IN/OUT) White
5 TD+ (RS-422/485), host Host interface (sender+) Pink
6 TD– (RS-422/485), host
TxD (RS-232), host
Host interface (sender-) Yellow
7 TxD (RS-232), Aux Aux interface (sender) Black
8 RxD (RS-232), AUX Aux interface (receiver+) Gray
9 SensGND Switching input ground White-black
10 Sensor 1 Digital switching input 1 Violet
11 RD+ (RS-422/485), host Host interface (receiver) Gray-pink
12 RD– (RS-422/485), host
RxD (RS-232), host
Host interface (receiver–) Red-blue
13 Result 1 Digital switching output 1 White-green
14 Result 2 Digital switching output 2 Brown-green
15 Sensor 2 Digital switching input 2 White-yellow
16 N. c. Yellow-brown
17 N. c. White-gray
14.4.1.2 “Power/SerialData/CAN/I/O” connection to customer-specific connection equipment or control cabi‐
net
Adapter cable suitable for drag chain, deep-freeze compatible
Part no. 2075220 (5 m), shielded, suitable for drag chain, deep-freeze compatible, suit‐
able for 2 A
For RFU63x, RFU65x
Permitted currents for ambient temperature +40 °C:
Contact 1 (blue) and contact 2 (brown): 2 A
All other contacts: 1.5 A
Ambient temperature range:
For mobile installation: –25 °C to +80 °C, for fixed installation: –40 °C to +85 °C
ANNEX 14
8014335/ZTL9/2018-10-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
99
Subject to change without notice

Table of Contents

Other manuals for SICK RFU62 Series

Related product manuals