ð
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
1 2
Figure 41: Adapter cable, part no. 2075220 (5 m)
1
Female connector, M12, 17-pin, A-coded (view from front)
2
Illustration may differ
Table 35: Signal assignment of adapter cable with open end
Pin Signal Function Wire color
1 GND Ground Blue
2 V
S
Supply voltage Brown
3 CAN L CAN bus (IN/OUT) Green
4 CAN H CAN bus (IN/OUT) White
5 TD+ (RS-422/485), host Host interface (sender+) Pink
6 TD– (RS-422/485), host
TxD (RS-232), host
Host interface (sender-) Yellow
7 TxD (RS-232), Aux Aux interface (sender) Black
8 RxD (RS-232), AUX Aux interface (receiver+) Gray
9 SensGND Sensor 1 switching input ground Gray-brown
10 Sensor 1 Digital switching input 1 Violet
11 RD+ (RS-422/485), host Host interface (receiver) Gray-pink
12 RD– (RS-422/485), host
RxD (RS-232), host
Host interface (receiver–) Red-blue
13 Result 1 Digital switching output 1 White-green
14 Result 2 Digital switching output 2 Brown-green
15 Sensor 2 Digital switching input 2 White-yellow
16 N. c. – Yellow-brown
17 N. c. – White-gray
14.4.2 “POWER” connection to customer-specific connection equipment (voltage supply) or control cabinet
Adapter cable
Part no. 6048319 (10 m), 2-wire, unshielded
For RFU630, RFU65x
Ambient temperature range:
With fixed installation: –25 °C to +80 °C
ð
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
1 2
Figure 42: Adapter cable, part no. 6048319 (10 m)
1
Female connector, M12, 17-pin, A-coded (view from front)
2
Illustration may differ
14 ANNEX
100
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x 8014335/ZTL9/2018-10-14 | SICK
Subject to change without notice