EasyManua.ls Logo

SICK RFU62 Series

SICK RFU62 Series
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 36: Signal assignment of adapter cable with open end
Pin Signal Function Wire color / charac‐
ters
1 Shield Gray
2 V
S
Supply voltage Red +
3 GND Ground Blue –
4
5
14.4.3 CDB650-204 or CDM420-0006 to CAN network connection module
Adapter cable
Part no. 6021166 (5 m), unshielded
Ambient temperature range:
For fixed installation: –40 °C to +70 °C, for mobile installation: –20 °C to +70 °C
ð
1
43
5
2
1 2
Figure 43: Adapter cable, part no. 6021166 (5 m) for connecting the connection module to the
CAN network
1
Female connector, M12, 5-pin, A-coded (view from front)
2
Illustration may differ
Table 37: Pin, signal and wire color assignments for the adapter cable with open end
Pin Signal Function Wire color
1 Shield
2 V
S
Supply voltage Red
3 GND Ground Black
4 CAN H CAN bus (IN/OUT) White
5 CAN L CAN bus (IN/OUT) Blue
14.4.4 Host interface RS-232 via CDB/CDM connection module to host (PC)
Device Connection module
RFU63x CDB650-204, CDM420-0006, -0007
RFU65x CDB650-204, CDM420-0006, -0007
Adapter cable
Part no. 2020319 (3 m), unshielded
Ambient temperature range:
For mobile installation: –5 °C to +90 °C, for fixed installation: –30 °C to +90 °C
ANNEX 14
8014335/ZTL9/2018-10-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
101
Subject to change without notice

Table of Contents

Other manuals for SICK RFU62 Series

Related product manuals