The data output triggered by means of a command string only occurs, however, at the
data interface on which the request was received.
6.3.5 RFU62x-105xx (PoE variant)
Service mode
The following functions can be executed via one of the three data interfaces (Aux 1, Aux
2 or Host 1):
Configuration
Read result display (detected transponder)
Transponder access (reading and writing of data)
Reading diagnostics (read result in a fixed output format)
For a detailed overview, see see "Using the data interfaces", page 46.
This is illustrated here for the Aux interface, the Aux port of the Ethernet interface, and
alternatively the USB interface. The USB interface is intended for temporary use only as
a servicing interface.
SOPAS ETSOPAS ET
PC
"Ethernet (Aux 1)"
EthernetEthernet
USBUSB
PoE Switch
(Endspan)
...
DC 48 V/57 V
PSE
**)
PD
*)
RFU62x-
105xx
*) PD = Powered Devices 6 **) PSE = Power Sourcing Equipment 5
"Ethernet"
Cable 2
Cable 1
4
"Ethernet (Aux 1/Host 1)/Power"
EthernetEthernet
"USB" (Aux 2),
for temporary use only 3
Configuration
Reading result
display
Transponder
access
Reading
diagnostics
Figure 19: Service mode, e.g. for read result display: Block diagram for the RFU62x-105xx
1
Adapter cable (male connector, M12, 8-pin, X-coded / male connector, RJ-45, 8-pin)
2
Adapter cable (male connector, USB, Micro-B type / male connector, USB, type A)
3
USB, alternative to Ethernet Aux port
4
Configuration using SOPAS ET, processed read result display, transponder access, or
reading diagnostics
5
PSE = Energy source
6
PD = Energy consumer
Read operation
In actual operation, the device outputs the read result to the further processing com‐
puter via the host interface. One of two configurable outputs formats can be selected
for this. The device can also output the same format or a second output format in paral‐
lel via the Aux interface.
For a detailed overview, see see "Using the data interfaces", page 46.
ELECTRICAL INSTALLATION 6
8015930/ZTM0/2018-11-06 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU62x