General information for all variants
1. RFU62x-101xx and RFU62x-104xx only:
If necessary, connect a read cycle trigger sensor, for example a photoelectric retro-
reflective sensor, to the “Sens 1” (CDB620), “SENS/IN1” (CDB650-204) or “Sen‐
sor 1” (CDM420) switching input of the connection module.
2. Supply the device with the required voltage, see "Supply voltage", page 57.
✓
After successful initialization, the “Device Ready” LED lights up green.
3. Turn on the PC and start Windows.
6.6.2 Block diagram: wiring the optional connection module
Device = RFU62x-101xx (Ethernet variant), RFU62x-104xx (serial variant)
NOTE
For possible combinations of the device and various connection modules, see table 14,
page 54
“V
S
”
“Sensor 2”
“Host 1”
“Aux 1”
“Result 2”
“Result 1”
“CAN”
“Sensor 2”
“Sensor 1”
“Sensor 1”
V
S
ß
“AUX”
PLC
CAN bus
“Result 1”
“Result 2”
CDB/CDM
Connection module 6
“Host 1”
“Aux 1”
RS-232
HOST/PLC
Further data
processing 8
PC
“Ethernet” (Host 2/Aux 2 5)
“USB” (Aux 3) 4
RS-232/422/485
Ethernet
USB
“Host 2”
Ethernet
“Aux 2”
“Aux 3”
1
ã
â
= á
CMC600
“External input 1”
“External input 2”
“External output 1”
“External output 2”
Interfaces 3
Transponder
Device 2
à 9
Configuration
Diagnostics
Transponder
access
Reading result
7
Figure 29: Connecting the device to peripherals via the optional connection module (overview)
1
Trigger sensor for start/stop read cycle (for example a photoelectric retro-reflective sen‐
sor)
2
Device
3
Interfaces
4
USB interface for temporary use only as a servicing interface
5
Ethernet: not supported for RFU62x-104xx (serial variant)
6
Connection module
7
Configuration using SOPAS ET, prepared representation of the read result, transponder
access or reading diagnostics
8
Data further processing
9
External digital switching outputs
ß
Supply voltage V
S
(V
S
= U
V
)
à
External digital switching inputs
ELECTRICAL INSTALLATION 6
8015930/ZTM0/2018-11-06 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU62x
53