EasyManua.ls Logo

SICK RFU62 Series

SICK RFU62 Series
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Switch setting Function
OFF CDB620-001 and device disconnected from supply voltage.
Recommended setting for all connection work.
14.5.3 Wiring serial host interface RS-232 of the device in CDB620-001
Device = RFU62x-104xx (serial variant), RFU62x-101xx (Ethernet variant)
Device
1 CDB620-001 Host
5
.
.
.
TxD
RxD
RxD
TxD
GND
GND
GND
12
1
9
7
6
43
T/TxD
44
R/RxD
42
GND
6
Shield
RS-232 RS-232
422
485
S6 : RS
ON
OFF
S7: Term 485
S6
422485
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
110
15
6
11
5
5 4
2
3
Figure 45: Wiring data interface RS-232 of the device in the connection module CDB620-001
1
Device
2
RFU62x-104xx (serial variant): connecting cable permanently connected with the device (male connector, D-Sub-HD,
15-pin)
3
RFU62x-101xx (Ethernet variant): adapter cable (male connector, D-Sub-HD, 15-pin / female connector, M12, 17-pin, A-
coded)
4
Connection module: female connector, D-Sub-HD, 15-pin
5
RFU62x-101xx (Ethernet variant): male connector, M12, 17-pin, A-coded
NOTE
Activate the RS-232 data interface in the device with a configuration tool, e.g. the con‐
figuration software SOPAS ET.
14.5.4 Wiring serial host interface RS-422 of the device in CDB620-001
Device = RFU62x-104xx (serial variant), RFU62x-101xx (Ethernet variant)
14 ANNEX
96
O P E R A T I N G I N S T R U C T I O N S | RFU62x 8015930/ZTM0/2018-11-06 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK RFU62 Series

Related product manuals