Residual risks of power drive systems
When carrying out a risk assessment of the machine in accordance with the EU Machinery
Directive, the machine manufacturer must consider the following residual risks associated
with the control and drive components of a power drive system (PDS).
1. Unintentional movements of driven machine components during commissioning,
operation, maintenance, and repairs caused by, for example:
Hardware defects and/or software errors in the sensors, controllers, actuators, and
connection technology
Response times of the controller and drive
Operating and/or ambient conditions not within the scope of the specification
Parameterization, programming, cabling, and installation errors
Use of radio devices / cellular phones in the immediate vicinity of the controller
External influences / damage
2. Exceptional temperatures as well as emissions of light, noise, particles, or gas caused by,
for example:
Component malfunctions
Software errors
Operating and/or ambient conditions not within the scope of the specification
External influences / damage
3. Hazardous shock voltages caused by, for example:
Component malfunctions
Influence of electrostatic charging
Induction of voltages in moving motors
Operating and/or ambient conditions not within the scope of the specification
Condensation / conductive contamination
External influences / damage
4. Electrical, magnetic and electromagnetic fields generated in operation that can pose a
risk to people with a pacemaker, implants or metal replacement joints, etc. if they are too
close.
5. Release of environmental pollutants or emissions as a result of improper operation of the
system and/or failure to dispose of components safely and corre
ctly.
More extensive information concerning the residual risks associated with the PDS is
provided in the relevant chapters of the technical user documentation.

Table of Contents

Other manuals for Siemens 1FT7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens 1FT7 and is the answer not in the manual?

Siemens 1FT7 Specifications

General IconGeneral
BrandSiemens
Model1FT7
CategoryEngine
LanguageEnglish

Related product manuals