Information on the application of motors   
7.6 Operation under vibrational or shock stress conditions 
  1FT7 Synchronous Motors 
234  Configuration Manual, (PFT7S) 01/2009, 6SN1197-0AD13-0BP2 
7.6  Operation under vibrational or shock stress conditions 
In order to ensure problem-free operation and a long service life, the vibration values defined 
in DIN ISO 10816 should not be exceeded.    
Table 7- 4  Vibration values 
Vibrational velocity V
rms
 [mm/s] acc. to DIN 
ISO 10816 
Frequency f [Hz]  Acceleration a [m/s
2
] 
4,5  10  0,4 
4,5  250  10 
Deviating from the specified standard, motors 1FT703 to 1FT710 may be operated with 
higher loads, with the restriction that the service life will be reduced. In this case, only 
operation outside the mounted natural frequency is permissible. 
 
Peak acceleration  Axial 20 m/s
2
  Radial 50 m/s
2
 
Shock duration   3 ms  3 ms 
7.7  Drive coupling 
Function description 
In order to achieve optimum drive-out characteristics, ROTEX
Ⓡ
 GS couplings supplied by 
KTR should be used. The advantages of ROTEX
Ⓡ
 GS couplings include:   
●  2 to 4x torsional stiffness of a belt-driven gearbox 
●  No intermeshing teeth (when compared to belt gearboxes) 
●  Low moment of inertia 
●  Good control behavior 
They must be optimally harmonized with existing machine masses, the mounted mechanical 
system, the machine stiffness, etc.  
KTR provides assistance in the selection of the coupling, refer to http://www.ktr.com