Description of the motors
1.5 Selection and ordering data
1FT7 Synchronous Motors
Configuration Manual, (PFT7S) 01/2009, 6SN1197-0AD13-0BP2
35
1FT7 Compact standard motors with liquid cooling
1)
The current carrying capacity of the power cables complies with EN 60204-1 for installation type C, for continuous duty at an ambient air
temperature of 40 °C (104 °F).
2)
With default setting of the pulse frequency.
3)
For version with gk 230 terminal box: Cable gland 2 x M32 x 1.5.
4)
With the specified Motor Module, the motor cannot be fully utilized with M
0
at ΔT = 100 K winding temperature rise.
If a Motor Module with a higher rating is used, you must check whether the specified power cable can be connected to it.
5)
Motor type
(continued)
Static
current
Calculated
power
P
calc
5)
SINAMICS S120 Motor Module Power cable with complete shield
3)
Motor connection (and brake connection)
via power connector
Rated
output
current
2)
Booksize format
I
0
at M
0
Δ
T=100 K
P
calc
for M
0
ΔT=100 K
I
rated
Power
connector
Cable
cross-
section
1)
Pre-assembled cable
AkW
(HP)
A Order No. Size mm
2
Order No.
1FT7062-5WF7...
1FT7064-5WF7...
1FT7066-5WF7...
1FT7068-5WF7...
7.4
11.9
14
19
3.1
5.0
6.3
9.4
(4.16)
(6.71)
(8.45)
(12.6)
9
18
18
18
4)
6SL3127 - 7 TE21 - 0AA3
6SL3127 - 7 TE21 - 8AA3
6SL3127 - 7 TE21 - 8AA3
6SL3127 - 7 TE21 - 8AA3
1
1
1
1
4 x 1.5
4 x 1.5
4 x 1.5
4 x 2.5
6FX7 002 - 57 S01 - ....
6FX7 002 - 57 S01 - ....
6FX7 002 - 57 S01 - ....
6FX7 002 - 57 S11 - ....
1FT7082-5WF7...
1FT7084-5WF7...
1FT7086-5WF7...
16
23
34
6.6
11.0
15.7
(8.85)
(14.8)
(21.1)
18
30
45
6SL3127 - 7 TE21 - 8AA3
6SL3127 - 1TE23 - 0AA3
6SL3127 - 1TE24 - 5AA3
1.5
1.5
1.5
4 x 2.5
4 x 4
4 x 6
6FX7 002 - 57 S31 - ....
6FX7 002 - 57 S41 - ....
6FX7 002 - 57 S54 - ....
1FT7102-5WF7...
1FT7105-5WF7...
1FT7108-5WF7...
40
53.2
65
15.7
28.3
39.3
(21.1)
(38.0)
(52.7)
45
60
85
6SL3127 - 1TE24 - 5AA3
6SL3127 - 1TE26 - 0AA3
6SL3127 - 1TE28 - 5AA3
1.5
3)
3
3)
3
3)
4 x 10
4 x 16
4 x 16
6FX7 002 - 57 S64 - ....
6FX7 002 - 57 S23 - ....
6FX7 002 - 57 S23 - ....
Cooling:
Internal air cooling
External air cooling
0
1
Motor Module:
Single Motor Module
Double Motor Module
Type of power cable:
MOTION-CONNECT 800
MOTION-CONNECT 500
Without brake cores
With brake cores
For length code as well as power and signal cables, see Connection system MOTION-CONNECT.
1
2
8
5
C
D
....
P
calc
[kW] =
M
0
[Nm] x n
rated
9550
P
calc
[HP] =
M
0
[Ib
f
-in] x n
rated
63000