Internal control/status words
Function diagrams
2-553
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Fig. 2-47 2510 – Status word 1 (r0052)
- 2510 -
Function diagram
87654321
FP_2510_97_01.vsd
Internal control/status words
G120 CU230P-2
13.12.2010 V4.4
Status word 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
ZSW 1
r0052
r0052
1 = Drive ready for switching on
0 = Drive not ready for switching on
1 = Drive ready for operation (DC link loaded, pulses disabled)
0 = Drive not ready for operation
1 = Drive running (voltage at output terminals)
0 = Pulses disabled
1 = Fault present (pulses disabled)
0 = No fault
0 = Coast down active (OFF2 active)
1 = No coast down active (OFF2 inactive)
0 = Fast stop active (OFF3 active)
1 = No fast stop active (OFF3 inactive)
1 = Switching on inhibited active
0 = No switching on inhibited (possible to switch on)
1 = Alarm present
0 = No alarm
0 = Deviation setpoint / actual speed
1 = No deviation setpoint / actual speed
1 = Control request (always 1)
1 = Maximum speed reached (f_act >= p1082 (f_max))
0 = f_act < p1082 (f_max)
0 = I,M,P limit reached
1 = Limit not reached
0 = Alarm motor overtemperature
1 = No motor overtemperature
1 = Motor rotates forwards
0 = Motor does not rotate forwards
0 = Alarm drive converter overload
1 = No drive converter overload
Signal "Fault active" is inverted if connected
to a digital output which means that the
relay will be in the de-energised state.
Bit No. Status word 1 (r0052)
ZSW seq_ctrl
r0899
r0899
.0
ZSW fault/alarm 1
r2139
r2139
ZSW seq_ctrl
r0899
r0899
ZSW seq_ctrl
r0899
r0899
ZSW seq_ctrl
r0899
r0899
ZSW seq_ctrl
r0899
r0899
ZSW seq_ctrl
r0899
r0899
ZSW fault/alarm 1
r2139
r2139
ZSW monitor 1
r2197
r2197
ZSW seq_ctrl
r0899
r0899
ZSW monitor 1
r2197
r2197
ZSW cl-loop ctrl
r0056
r0056
ZSW fault/alarm 2
r2135
r2135
ZSW monitor 1
r2197
r2197
ZSW fault/alarm 2
r2135
r2135
.1
.2
.3
.4
.5
.6
.7
.7
.7
.6
.13
.14
.3
.15
r0052.0
r0052.1
r0052.4
r0052.5
r0052.11
r0052.2
r0052.6
r0052.9
r0052.13
r0052.14
r0052.15
r0052.3
r0052.7
r0052.8
r0052.10
[2503.7]
[2503.7]
[2503.7]
[2548.7]
[2503.7]
[2503.7]
[2503.7]
[2548.7]
[2534.7]
[2503.7]
[2534.7]
[2526.7]
[2548.7]
[2534.7]
[2548.7]
Reserved
<1>
r0052.3 displays status bit r2139.3 or r1214.10, if p1210 > 0
<1>

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals