Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2016, FW V4.7 SP6, A5E34259001B AC
5
Changes in this manual
Notable changes since the 04/2015 edition of the manual
New hardware
New Power Module PM240-2, FSF
Power Module (Page 31)
New functions in firmware V4.7 SP6
Evaluation of a PT1000 motor temperature sensor
Motor temperature monitoring using a temperature sensor (Page 265)
Revision of the thermal motor models: p0612 bit 08, 09 and 12
Protecting the motor by calculating the motor temperature (Page 269)
Support for 1PC1 induction motors
Supported motor series (Page 49)
Changing the quick commissioning in the "Standard Drive Control" application class:
The motor data identification is no longer permanently set to p1900 = 12; instead, users
select the appropriate motor data identification.
Factory setting: p1900 = 2.
Standard Drive Control (Page 154)
Standard Drive Control (Page 135)
You can find an overview of all new and modified functions in firmware V4.7 SP6:
New and extended functions (Page 477)
Corrections
The "Moment of inertia estimator" function has been released for all permitted motors.
Moment of inertia estimator (Page 254)
It is not permissible that the output of the friction characteristic r3841 is interconnected
with p1511 or with p1513.
Friction characteristic (Page 252)