Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2016, FW V4.7 SP6, A5E34259001B AC
477
New and extended functions
Table A- 1 New functions and function changes in firmware 4.7 SP6
1
Support for the Power Module PM240-2, FSF frame sizes
Support for safety functions Safe Torque Off (STO) via the
terminals of the Power Module PM240-2 FSF frame size
You can find additional information in the "Safety Integrated"
function manual.
Overview of the manuals (Page 507)
- - - - ✓ ✓ - - -
Support for Power Module PM330 JX frame size
Support for 1PC1 induction motors
4 The control of synchronous reluctance takes into account the
inductance of the output reactor.
- - ✓ - - - - - -
Support for motor temperature sensor PT1000
New p4621 parameter for disabling PTC short-circuit monitoring
7 Revision of the thermal motor model for protecting the motor
against damage due to overheating in the stator or rotor
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
8 Changing the quick commissioning in the "Standard Drive Con-
trol" application class:
The motor data identification is no longer permanently set to
p1900 = 12; instead, users select the appropriate motor data
identification.
Factory setting: p1900 = 2.
- ✓ ✓ ✓ ✓ ✓ - - -
9 The free function blocks are also available in the SINAMICS
✓ ✓ ✓ ✓ ✓ ✓ ✓ - -
Changes in this manual (Page 5)