Input/Output Terminals
Function diagrams
2-517
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 01/2011
Fig. 2-16 9568 – Analog input 2 (AI2)
- 9568 -
Function diagram
87654321
FP_9568_97_01.vsd
External Interfaces
G120 CU230P-2
13.12.2010 V4.4
Analog input 2 (AI2)
3
3
20 mA
T0
<2>
0  20 mA
°C
Kl.50
[%]
xy
<2> <2>
A
D
+
-
<1>
<1>
x
1
y
2
x
2
y
1
y
x
[%]
y
x
2
x
1
<2> <3>
% 100
xx
21
<3>
AI2 TEMP   I
1
0
20 mA
1
0
Current
Hardware smoothing
100 μs
Scaling
Caution:
The voltage between an input (Kl.50) and the ground point (Kl.51) must not exceed 35 V.
When the load resistor is switched in (DIP switch in position I), the voltage between the input terminals
must not exceed 10 V or the impressed current 80 mA.
For p0756 = 2, 3 the units are mA.
For p0756 = 6, 7 the units are °C.
Possible settings p0756[2]:
= 2: 0 mA ... +20 mA (Default for AI2)
= 3: 4 mA ... +20 mA with monitoring
= 6: Ni1000
= 7: PT1000
= 8: No sensor
F03505
"Wire
breakage"
CU wire brk t_del
0 ... 1000 [ms]
p0762 (100)
CU AI sim_mode
0 ... 1
p0797 (0)
CU AI type
0 ... 8
p0756 (4)
CU WireBrkThresh
0.00 ... 20.00
p0761 (2.00)
CU AI T_smooth
0.0 ... 1000.0 [ms]
p0753 (0.0)
CU AI sim setp
-50.000 ... 2000.000
p0798 (0.000)
CU AI char y1
-1000.00 ... 1000.00 [%]
p0758 (0.00)
CU AI char y2
-1000.00 ... 1000.00 [%]
p0760 (100.00)
CU AI char x1
-50.000 ... 160.000
p0757 (0.000)
CU AI char x2
-50.000 ... 160.000
p0759 (10.000)
CU AI sim_mode
0 ... 1
p0797 (0)
Kl.51
Kl. = Terminal
Sampling time of the AI : 4 ms
r0755
CU AI value in % [%]
[2]
Ni1000
PT1000
°C
Ni1000/PT1000
<4>
Wire breakage sensing only activated when p0756 = 3.
<2>
<4>
<2>
Type switching
Analog input
I
GND
[2] (0)
[2] (2)
[2] (0.00)
[2] (100)
[2] (0)
[2] (0.00)
[2] (0.00)
[2] (0.00)
[2] (0.00) [2] (0.00)
[2] (0.00)
CU AI status word
r0751
r0752
CU AI U/I_inp act
[2]
Reference
quantities
p2000  r2004

Table of Contents

Other manuals for Siemens CU240B-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240B-2 and is the answer not in the manual?

Siemens CU240B-2 Specifications

General IconGeneral
BrandSiemens
ModelCU240B-2
CategoryInverter
LanguageEnglish

Related product manuals