Appendix
A.1 New and extended functions
Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2016, FW V4.7 SP6, A5E34259001B AC
479
Function
SINAMICS
G120
G120D
12 SINAMICS “Standard Drive Control” and “Dynamic Drive Con-
trol” application classes to simplify commissioning and increase
the degree of ruggedness of the closed-loop motor control.
The SINAMICS application classes are available with the fol-
lowing inverters:
SINAMICS G120C
SINAMICS G120 with PM240, PM240-2 and PM330 Power
Modules
- - - -
13 Moment of inertia estimator with moment of inertia precontrol to
optimize the speed controller in operation
-
14 Friction torque characteristic with automatic plotting to optimize
the speed controller
-
15
Automatic optimization of the technology controller
-
-
-
-
-
-
16 The sign of the system deviation for the additional, free tech-
nology controller can be switched over.
A new parameter defines the sign of the system deviation
matching the particular application, e.g. for cooling or heating
applications.
- - - - - - - -
17 The technology controller output can be enabled and disabled
during operation
- - - -
18 Ramp-function generator remains active with enabled technol-
ogy controller
- - - - - - - -
19 Line contactor control using a digital output of the inverter to
save energy when the motor is switched off
-
20 Fast flying restart for PM330 Power Modules:
The "Flying restart" function does not have to wait for the motor
demagnetization time, and identifies the motor speed without
requiring a search operation.
- - - - - - - -
21 Load torque monitoring extended to include the following func-
tions:
Protection against blocking, leakage and dry running opera-
tion in pump applications
Protection against blocking and broken belts in fan applica-
tions
- - - - -
22
Automatic switchover of the real time clock from daylight saving
time (summer time) to standard time (winter time).
- - - - - - - -
23 New or revised default settings of the interfaces: p0015 macros
110, 112 and 120
- - - - - - - -
24 Expansion of the temperature sensors to include DIN-Ni1000
for analog inputs AI 2 and AI 3
- - - - - - - -