Configuring/address space
4.3 Pulse train mode
Technology Module TM Pulse 2x24V (6ES7138‑6DB00‑0BB1)
72 Manual, 05/2019, A5E35061186-AB
Parameter
Value range
Scope
On delay for pulse output
0...85000000 μs
Channel
Duty cycle
Dependent on the output format
Channel
1
When configuring with HSP for STEP 7 or with a GSD file, you define the channel configuration by
the selection of the module name.
Note
PROFIBUS GSD configuration
When configuring with a PROFIBUS GSD file, the possible parameter assignments are not
available. The
parameters are preassigned in the module with the default setting. Set the
"Pulse train" mode and the further parameters in the user program using data record 128.