When assessing the machine's risk in accordance with the respective local regulations (e.g.,
EC Machinery Directive), the machine manufacturer must take into account the following
residual risks emanating from the control and drive components of a drive system:
1. Unintentional movements of driven machine components during commissioning, operation,
maintenance, and repairs caused by, for example,
Hardware and/or software errors in the sensors, control system, actuators, and cables
and connections
Response times of the control system and of the drive
Operation and/or environmental conditions outside the specification
Condensation/conductive contamination
Parameterization, programming, cabling, and installation errors
Use of wireless devices/mobile phones in the immediate vicinity of the control system
External influences/damage
2. In the event of a fault, exceptionally high temperatures, including an open fire, as well as
emissions of light, noise, particles, gases, etc. can occur inside and outside the inverter,
e.g.:
Component failure
Software errors
Operation and/or environmental conditions outside the specification
External influences/damage
Inverters of the Open Type/IP20 degree of protection must be installed in a metal control
cabinet (or protected by another equivalent measure) such that contact with fire inside and
outside the inverter is not possible.
3. Hazardous shock voltages caused by, for example,
Component failure
Influence during electrostatic charging
Induction of voltages in moving motors
Operation and/or environmental conditions outside the specification
Condensation/conductive contamination
External influences/damage
4. Electrical, magnetic and electromagnetic fields generated in operation that can pose a risk
to people with a pacemaker, implants or metal replacement joints, etc., if they are too close
5. Release of environmental pollutants or emissions as a result of improper operation of the
system and/or failure to dispose of components safely and correctly
General information and networking