Parameter Range of values Default setting Meaning
SessionNumber = Number
Password = String
SuspendLock = Number 0 or 1 0 0: No displacement disable
1: Displacement disable set
SuspendPriority = Number 1 ... 10 1 1: Lowest priority
10: Highest priority
StartupPrio = Number Boot sequence:
The lower the number the higher
the priority
ScreenOnFocus = String | Number Not relevant
ChannelOnFocus = Number Not relevant
[host_1]
Address = [hostname | IP-Adresse] From data file structure
SessionNumber = NUMBER
Password = STRING
SuspendLock = NUMBER 0 or 1 0 0: No displacement disable
1: Displacement disable set
SuspendPriority = NUMBER 1 ... 10 1 1: Lowest priority
10: Highest priority
StartupActive = 0 0 or 1 Display screen after boot
StartupPrio = NUMBER 0 ... not too high Boot sequence:
The lower the number the higher
the priority
ScreenOnFocus = STRING | NUMBER Not relevant
ChannelOnFocus = NUMBER Not relevant
[host_2]
...
[host_MaxHostIndex]
[T2M2N]
SK1 = ch_grp x 2 x 8 characters Empty Softkey inscription (2 lines)
SK2 = ch_grp x 2 x 8 characters Empty Softkey inscription (2 lines)
SK3 = ch_grp y 2 x 8 characters Empty Softkey inscription (2 lines)
...
SK32 = ch_grp z 2 x 8 characters Empty Softkey inscription (2 lines)
...
General information and networking
1.4 Networking
Handheld Terminal HT 8
Manual, 07/2015, A5E36371621B-AB 67