5 System Parameters Issue 03/01
MICROMASTER 411 & COMBIMASTER 411 Operating Instructions
72
6SE6400-5CA00-0BP0
Command and Digital I/O (P0004 = 7)
ParNr ParText Default Acc WS QC
r0002 Drive state - 2 - -
r0019 CO/BO: BOP control word - 3 - -
r0052 CO/BO: Act. status word 1 - 2 - -
r0053 CO/BO: Act. status word 2 - 2 - -
r0054 CO/BO: Act. control word 1 - 3 - -
r0055 CO/BO: Act. control word 2 - 3 - -
P0700[1] Selection of command source 2 1 CT Q
P0701[1] Function of digital input 1 1 2 CT N
P0702[1] Function of digital input 2 12 2 CT N
P0703[1] Function of digital input 3 9 2 CT N
P0704[1] Function of digital input 4 0 2 CT N
P0705[1] Function of digital input 5 0 2 CT N
r0720 Number of digital inputs - 3 - -
P0719[2] Selection of cmd. & freq. setp. 0 3 CT N
r0722 CO/BO: Binary input values - 2 - -
P0724 Debounce time for digital inputs 3 3 CT N
r0730 Number of digital outputs - 3 - -
P0731[1] BI: Function of digital output 1 52:3 2 CUT N
r0747 CO/BO: State of digital outputs - 3 - -
P0748 Invert digital outputs 0 3 CUT N
P0800[1] BI: Download parameter set 0 0:0 3 CT N
P0801[1] BI: Download parameter set 1 0:0 3 CT N
P0810 BI: CDS bit 0 (Local / Remote) 0:0 2 CUT N
P0840[1] BI: ON/OFF1 722:0 3 CT N
P0842[1] BI: ON reverse/OFF1 0:0 3 CT N
P0844[1] BI: 1. OFF2 1:0 3 CT N
P0845[1] BI: 2. OFF2 19:1 3 CT N
P0848[1] BI: 1. OFF3 1:0 3 CT N
P0849[1] BI: 2. OFF3 1:0 3 CT N
P0852[1] BI: Pulse enable 1:0 3 CT N
P1020[1] BI: Fixed freq. selection Bit 0 0:0 3 CT N
P1021[1] BI: Fixed freq. selection Bit 1 0:0 3 CT N
P1022[1] BI: Fixed freq. selection Bit 2 0:0 3 CT N
P1035[1] BI: Enable MOP (UP-command) 19:13 3 CT N
P1036[1] BI: Enable MOP (DOWN-command) 19:14 3 CT N
P1055[1] BI: Enable JOG right 0:0 3 CT N
P1056[1] BI: Enable JOG left 0:0 3 CT N
P1074[1] BI: Disable additional setpoint 0:0 3 CUT N
P1110[1] BI: Inhibit neg. freq. setpoint 0:0 3 CT N
P1113[1] BI: Reverse 722:1 3 CT N
P1124[1] BI: Enable JOG ramp times 0:0 3 CT N
P1140[1] BI: RFG enable 1:0 3 CT N
P1141[1] BI: RFG start 1:0 3 CT N