EasyManua.ls Logo

Siemens MICROMASTER 440 - How to Remove I;O Card to Get at Switches

Siemens MICROMASTER 440
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 08/03
34 Quick Start Guide MICROMASTER 440
6SE6400-5GA00-0BP0
3.1 How to Remove I/O Card to Get At Switches
The 50/60Hz DIP switch is located underneath the I/O card on ALL frame sizes of MM440. In the top
right hand corner of the I/O board there is a clip that can be released using a flat bladed screwdriver.
Using the plastic bulge (over the relays on the I/O board), you can hold the I/O board and remove it
easily once the clip has been released.
See following illustrations for instructions on removing the I/O boards in the different frame sizes.
3.1.1 Frame Size A to Frame Size C
1 Remove SDP or
BOP by pressing
button.
2 Slide down
terminal cover
3 Use flat blade
screwdriver to
remove I/O board
50/60 Hz DIP
switch is on right.
Down = 50Hz,
Up = 60Hz
4 Move DIP switch
2(2) according to
nominal motor
frequency
DIP2(1) has
no function
Figure 3-1 Removing the I/O board on Frame Size A to Frame Size C MM440
NOTE
Example shown is Frame Size A; Frame Size B & Frame Size C are similar.
www . ElectricalPartManuals . com