EasyManua.ls Logo

Siemens Milltronics BW500 - P350 Calibration Security; Online Calibration Options (P355 - P358); P355 Online Calibration Feature; P356 Online Calibration Reference Weight

Siemens Milltronics BW500
220 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
12.5 Online Calibration Options (P355 - P358)
BW500 and BW500/L
168 Operating Instructions, 12/2016, A5E33482052-AD
12.4.3
P350 Calibration Security
P350 Calibration Security
zero
Span
‘Reset T’
entry: 0 = no additional
security.
f
Yes Yes Yes
1 = in addition to
P000 lock; no
span.
Yes No Yes
2 = in addition to
P000; no zero, no
span.
No No Yes
3 = in addition to
P000; no zero, no
span, no totalizer
1 (T1) reset.
No No No
12.5
Online Calibration Options (P355 - P358)
Note
Online calibration options must be enabled (P355 = 1) before they become available.
Not available with BW500/L.
12.5.1
P355 Online Calibration Feature
Enables Online Calibration.
Entry:
0 = OFF
f
1 = ON
12.5.2
P356 Online Calibration Reference Weight
Enter the weigh bin reference weight, (in units selected in P005), range 0.000 to 99999 (