5.2 Installation of NE8000 cabinets
5.2.1 NE8000 hardware requirements
Environmental requirements
The cabinets for NK822x should always be installed in a clean and safe environ-
ment, away from dust, high temperature and humidity, vibrations and impacts.
Conditions should match the specific requirements given in the Technical data sec-
tion on p. 57.
NK8000 power requirements
Item Power supply requirement
Input voltage 100-240 Vac, 50-60Hz
Input current 2A
A switch-box including a bipolar cut-out (phase + neutral) is required in the elec-
trical installation.
5.2.2 NE8000 hardware installation
Cabinet installation
1. The cabinet is typically wall-mounted. A proper support must be provided for the
maximum weight (see Technical data on p. 57). Four supporting screws or
hooks (min.10 mm) are required as shown in Fig. 23.