According to the clamp pressure of chuck in clamp status, chucking lamp in operation 
panel will be operated as follows. 
Low pressure ; flickering 
 
The setting of actual pressure in low and high pressure can be adjusted using chucking 
pressure change valve that is attached at the front of machine. The setting pressure will 
be upped by rotating the knob of valve in CW direction and downed in CCW direction. 
In general, the setting pressure is set as follows at shipping. According to the machine 
type, setting pressure may be differ. 
-  Low pressure : 5kgf/cm
2
 
-  High pressure : 20 ~ 25Kgf/cm
2
 
 
(2)  Operation restrictions in dual chucking according to the setting of MD  
According to the setting of MD, operation status of chucking would be changed. 
If  M-code  that  changes  chucking  pressure  is  commanded, 
rotating spindle will stop and be changed into  feed hold status. 
And  alarm  700165  occurs.  Alarm  700165  will  be  cleared  by 
unclamping in manual. Automatic operation can be restarted after 
clamping again. 
If  M-code  that  changes  chucking  pressure  is  commanded, 
rotating spindle isn't stop. And the machine will keep on operation 
without stop and any occurrence of alarm. 
After ON the machine power, it is possible to command spindle 
rotation  automatically  without  M-code  command  related  to 
chucking pressure change. 
After  ON  the  machine  power,  if spindle  rotation  is  commanded 
automatically  without  M-code  command  related  to  chucking 
pressure change, alarm 700060 will occur. After ON the machine 
power,  surely  command  once  M-code  related  to  chucking 
pressure change. After this, spindle rotation can be commanded 
normally. 
Machine data shown above is set to "0" at shipping.