Safety notices
2.1 Recommendations on network security
SCALANCE XC-200
14 Operating Instructions, 07/2016, C79000-G8976-C442-01
Secure/non-secure protocols and services
Avoid or disable non-secure protocols and services, for example Telnet and TFTP. For
historical reasons, these protocols are available, however not intended for secure
applications. Use non-secure protocols on the device with caution.
Check whether use of the following protocols and services is necessary:
Non authenticated and unencrypted ports
MRP, HRP
IGMP snooping
LLDP
Syslog
RADIUS
DHCP Options 66/67
TFTP
GMRP and GVRP
The following protocols provide secure alternatives:
HTTP HTTPS
Telnet SSH
SNMPv1/v2c SNMPv3
Check whether use of SNMPv1/v2c. is necessary. SNMPv1/v2c is classified as non-
secure. Use the option of preventing write access. The device provides you with
suitable setting options.
If SNMP is enabled, change the community names. If no unrestricted access is
necessary, restrict access with SNMP.
Use the authentication and encryption mechanisms of SNMPv3.
Use secure protocols when access to the device is not prevented by physical protection
measures.
If you require non-secure protocols and services, operate the device only within a
protected network area.
Restrict the services and protocols available to the outside to a minimum.
For the DCP function, enable the "Read Only" mode after commissioning.
If you use RADIUS for management access to the device, activate secure protocols and
services.

Table of Contents

Other manuals for Siemens SCALANCE XC-200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XC-200 and is the answer not in the manual?

Siemens SCALANCE XC-200 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XC-200
CategorySwitch
LanguageEnglish

Related product manuals