Technical specifications
7.7 Mechanical stability (in operation)
SCALANCE XC-200
70 Operating Instructions, 07/2016, C79000-G8976-C442-01
Technical specifications
Installation options
Wall mounting
Installation on a DIN rail
Mounting on an S7-300 standard rail
Mounting on an S7-1500 standard rail
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C)
> 41 years
Switching properties
Aging time
45 seconds
Max. number of learnable MAC ad-
dresses
2048
Response to LLDP frames
Blocking
Response to spanning tree BPDU
frames
Forwarding
CoS acc. to IEEE 802.1Q
Yes
QoS priority queues
4
1)
Note the wiring rules (Page 49).
7.7
Mechanical stability (in operation)
Mechanical stability (in operation)
Device
IEC 60068-2-27 shock
IEC 60068-2-6 vibration
15 g, 11 ms duration
6 shocks per axis
10 - 58 Hz: 0.075 mm
85 - 150 Hz: 1 g
1 octave/min, 20 sweeps
SCALANCE XC206-2 (ST/BFOC)
SCALANCE XC206-2 (SC)
SCALANCE XC206-2SFP
SCALANCE XC208
SCALANCE XC216
SCALANCE XC224