EasyManua.ls Logo

Siemens SCALANCE XF200 - LED Status Indicators

Siemens SCALANCE XF200
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the device
2.2 The LEDs
SCALANCE X-200
Operating Instructions, 03/2015, C79000-G8976-C284-06
17
2.2
The LEDs
2.2.1
LED display when the device starts up
When the X-200 starts up, the LEDs light up in the following sequence:
The green power LED lights up immediately after turning on the device.
The LEDs of the Ethernet connectors light up for approximately 6 seconds.
When the Ethernet LEDs go off, the red fault LED is lit for approximately 20 seconds.
Following this, after approximately 2 seconds the correct link status is displayed.
The X-200 is now ready for operation.
2.2.2
Power LED "L" (green/yellow LED)
The power LED shows the status of the power supply on the X-200 IE switch. The power
LED can light up either green or yellow. The meanings of the display are as follows:
LED color
LED status
Meaning
Green
Lit
Both power supplies are connected; in other words, redundant power supply.
Yellow Lit Only one power supply is connected.
- Off No power supply is connected or the voltage is < 14 VDC or with TS devices < 8
VDC.
Note
The following devices do not have a redundant power supply:
X201-3P IRT PRO
X202-2P IRT PRO
X204IRT PRO