Technical specifications
SCALANCE X-200
Operating Instructions, 03/2015, C79000-G8976-C284-06
69
Type
Connectors for end devic-
es or network compo-
nents via twisted pair
RJ-45 jacks with MDI X
pinning
10/100 Mbps half / full
duplex
Connections for end
devices or network com-
ponents via FO cable
SC RJ jacks (push-pull),
100 Mbps, full duplex to
100BaseFX
Connector for power
supply
5-pin Power Plug PRO
connector (male)
Connector for signaling
contact
5-pin b-coded M12 con-
nector (male)
X201-3P IRT PRO
1
3
2
1
X202-2P IRT PRO
2
2
2
1
X204IRT PRO
4
-
2
1
Signaling contact
The following applies to all devices:
Voltage for the signaling contact: 24 VDC
Current through the signaling contact: maximum 100 mA
Electrical data
Type
Supply voltage with re-
dundant connection
Rated voltage 12 to 24
VDC SELV
Voltage range 10 VDC to
28.8 VDC
Permitted voltage range
incl. total ripple 10 VDC to
30.2 VDC
Power loss at 12 VDC
Current consumption at
rated voltage
Overcurrent protection at
input
Non-replaceable fuse (F)
X204-2TS
+
6.60 W
600 mA
3.0 A / 32 V
X204-2LD TS
+
6.60 W
600 mA
3.0 A / 32 V
Type
Supply voltage with re-
dundant connection
Rated voltage 24 VDC
Voltage range 19.2 VDC
to 28.8 VDC
Permitted voltage range
incl. total ripple 18.5 VDC
to 30.2 VDC
Power loss at 24 VDC
Current consumption at
rated voltage
Overcurrent protection at
input
PTC resettable fuse
X204-2
+
6.36 W
265 mA
600 mA / 60 V
X204-2FM
+
6.36 W
265 mA
600 mA / 60 V
X204-2LD
+
6.36 W
265 mA
600 mA / 60 V
X206-1
+
5.28 W
220 mA
600 mA / 60 V
X206-1LD
+
5.28 W
220 mA
600 mA / 60 V
X208
+
3.84 W
185 mA
600 mA / 60 V
X208PRO
+
4.4 W
185 mA
600 mA / 60 V
X212-2
+
7.92 W
330 mA
1.1 A / 33 V
X212-2LD
+
7.92 W
330 mA
1.1 A / 33 V