Installation
4.4 Installation on a standard rail
SCALANCE X-200
38 Operating Instructions, 03/2015, C79000-G8976-C284-06
4.4
Installation on a standard rail
Installation on a SIMATIC S7-300 standard rail
To install an X-200 on a standard rail, follow the steps below:
1. Fit the housing guide on the top of the housing into the standard rail.
2. Screw the X-200 to the underside of the standard rail.
3. Fit the connectors for the power supply.
4. Fit the connectors for the signaling contact.
5. Insert the terminal blocks or M12 cable connectors into the sockets on the X-200.
Figure 4-3 Installation on a SIMATIC S7-300 standard rail
Removal
To remove an X-200 from a standard rail, follow the steps below:
1. First disconnect all connected cables.
2. Release the screws on the bottom of the standard rail.
3. Then lift the X-200 away from the standard rail.