Connecting up
5.5 Attachment to Industrial Ethernet
SCALANCE X-200
Operating Instructions, 03/2015, C79000-G8976-C284-06
51
5.5
Attachment to Industrial Ethernet
Note
Redundancy mechanisms
If you use redundancy mechanisms such as media redundancy "HRP" or "MRP" and/or
redundant linking of rings via a standby link, remember the following:
Open the redundant path before you insert a new device or replacement device in an
operating network. A
bad configuration or attachment of the Ethernet cables to incorrectly
configured ports causes overload in the network and a breakdown in communication.
A device may only be inserted in a network and connected in the following situations:
HRP / MRP
The ring ports of the device being inserted in the ring were configured as ring ports.
The required redundancy mode is also enabled.
If the device is intended to operate as the redundancy manager, "Enable Ring
Redundancy" must also be set.
Standby link
Select "Enable Standby Master".
The "Standby Connection Name" must match the name of the partner device.
You must also configure the standby port.
You will find detailed information in the SCALANCE X
-200 configuration manual.
5.5.1
Electrical connections
5.5.1.1
Electrical attachments to Industrial Ethernet
Connection via RJ-45 jacks
The electrical connectors for Industrial Ethernet on the X-200 IE switch are designed as RJ-
45 jacks with the following properties:
MDI-X assignment
Autonegotiation
Auto polarity exchange