Connecting up
5.3 Grounding
SCALANCE X-200
48 Operating Instructions, 03/2015, C79000-G8976-C284-06
5.3
Grounding
Grounding when installing on a DIN rail
The device is grounded over the DIN rail.
Grounding when installing on an S7 standard rail
The device is grounded over its rear panel and the neck of the screw.
Grounding with wall mounting
The device is grounded by the securing screw in the unpainted hole.
Please note that X-200 IE switches must be grounded over one securing screw with
minimum resistance.
If an IE Switch X-200 is mounted on a non-conducting base, a grounding cable must be
installed. The grounding cable is not supplied with the device. Connect the paint-free surface
of the device to the nearest grounding point using the grounding cable.