Technical specifications
SCALANCE X-200
70 Operating Instructions, 03/2015, C79000-G8976-C284-06
Type
Supply voltage with re-
dundant connection
Rated voltage 24 VDC
Voltage range 19.2 VDC
to 28.8 VDC
Permitted voltage range
incl. total ripple 18.5 VDC
to 30.2 VDC
Power loss at 24 VDC
Current consumption at
rated voltage
Overcurrent protection at
input
PTC resettable fuse
X216
+
5.76 W
240 mA
1.1 A / 33 V
X224
+
8.40 W
350 mA
1.1 A / 33 V
XF204
+
2.64 W
110 mA
1.1 A / 33 V
XF204-2
+
5.28 W
220 mA
1.1 A / 33 V
XF206-1
+
4.08 W
170 mA
1.1 A / 33 V
XF208
+
3.12 W
130 mA
1.1 A / 33 V
X200-4P IRT
+
9.6 W
400 mA
1.1 A / 33 V
X201-3P IRT
+
8.4 W
350 mA
1.1 A / 33 V
X201-3P IRT PRO
no redundancy
7.2 W
300 mA
1.1 A / 33 V
X202-2IRT
+
6.0 W
300 mA
600 mA / 60 V
X202-2P IRT
+ 7.2 W 300 mA 1.1 A / 33 V
X202-2P IRT PRO
no redundancy
7.2 W
300 mA
1.1 A / 33 V
X204IRT
+
4.8 W
200 mA
600 mA / 60 V
X204IRT PRO
no redundancy
4.8 W
200 mA
600 mA / 60 V
XF204IRT
+ 4.8 W 200 mA 600 mA / 60 V
Optical data
Type
Transmitter output (optical)
Receiver input
min. [dBm]
max. [dBm]
Sensitivity min. [dBm]
Input power max. [dBm]
X204-2
X204-2TS
X204-2FM
X206-1
X212-2
XF204-2
XF206-1
X202-2IRT
-19 -14 -32 -3
X204-2LD
X204-2LD TS
X206-1LD
X212-2LD
-15 -8 -34 -3
X200-4P IRT
X201-3P IRT
X201-3P IRT
PRO
X202-2P IRT
X202-2P IRT
PRO
-8 -2 -23 +1