Test of mechanical stability
SCALANCE X-200
84 Operating Instructions, 03/2015, C79000-G8976-C284-06
Device type
SCALANCE
IEC 60068-2-6 vibration
IEC 60068-2-27 shock
XF206-1
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 6 ms duration
6 shocks per axis
XF208
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 6 ms duration
6 shocks per axis
X200-4P IRT
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
X201-3P IRT
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
X201-3P IRT PRO
5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
10 cycles per axis
15 g, 11 ms duration
6 shocks per axis
X202-2IRT
10 - 58 Hz: 0.075 mm
58 - 500 Hz: 1 g
10 cycles per axis
10 g, 16 ms duration
6 shocks per axis
X202-2P IRT
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
X202-2P IRT PRO
5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
10 cycles per axis
15 g, 11 ms duration
6 shocks per axis
X204IRT
10 - 58 Hz: 0.075 mm
58 - 500 Hz: 1 g
10 cycles per axis
10 g, 16 ms duration
6 shocks per axis
X204IRT PRO
5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
10 cycles per axis
15 g, 11 ms duration
6 shocks per axis
XF204IRT
10 - 58 Hz: 0.075 mm
58 - 500 Hz: 1 g
10 cycles per axis
10 g, 16 ms duration
6 shocks per axis
Note
The interfaces of the X
-200 IE switches can be divided into groups each with 4 ports:
P1 to P4
P5 to P8
P9 to P12
etc.
If only ports of different port groups are used, the device meets the requirements for
Environment B in compliance with IEEE 802.3, Section 33.4.1.1. If ports of the same port
group are used, the requirements for Environment A are met.