EasyManua.ls Logo

Siemens SIMATIC FM 353 - Set Actual Value On-The-Fly (Write Request in the User DB, DBX39.0)

Siemens SIMATIC FM 353
361 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of Functions
9-49
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
9.3.6 Set actual value on-the-fly (Write request in the user DB,
DBX39.0)
Overview
You can use this function to assign a new value to the actual value by means of an
external event.
Function of set actual value on-the-fly
By transmitting the coordinates (new actual value), set actual value on-the-fly is
activated.
However, the Set Actual Value function is not triggered via the appropriate digital
input until “Processing in progress” = 1.
Set actual value on-the-fly can be activated again by transmitting Set actual value
on-the-fly again.
The coordinates can be reset to their original value by:
S Including synchronization in Reference Point Approach mode
S Set reference point
S Remove setting actual value
S Restart
Note:
For “set actual value on-the-fly” in “Automatic” mode, see Section 9.2.6