Wiring
4-12
FM 353 Stepper Drive Positioning Module
6ES7 353-1AH01-8BG0
Identification of the connecting cable
The connecting cable is a cable set for one axis with an analog interface. The ter-
minals are identified for SIMODRIVE drive units.
Order No.: 6FX2 002-3AC01-1VV0
The connecting cable is available in a variety of lengths.
see Catalog NC Z , Order No.: E86060-K4490-A001-AV.
4.4 Description of the I/O interface
Front connector
Four digital inputs/outputs and one message signal from the power section may be
connected to the 20-pin front connector X1 with its single-wire terminal.
Location of connector
Figure 4-6 shows the front connector in position to be wired, and the labeling on
the inside of the front door.
X1
Labeling on in-
side of front door
Front connector in wiring position
X1
3
4
5
6
9
10
12
13
14
20
19
L+
M
11
1
2
3
4
5
6
7
8
9
1
1
1
1
1
1
1
1
1
1
2
0
0
1
2
3
4
5
6
7
8
9
Locking device
Fig. 4-6 Location of X1 connector